1 LSI Software RAID Configuration UtilityThe MegaRAID Storage Manager MSM program provides you with graphical user interface GUI tools to configure RAID storage systems, based on the LSI 106x controllers used in some of the x64 servers. 6.2.6 Deleting a RAID configuration.6-21 6.2.7 Selecting the boot drive from a RAID set.6-22 6.2.8 Enabling WriteCache. 6-4 6.2.1 Creating a RAID set. Download drivers for lsi embedded megaraid.6.2 LSI Software RAID Configuration Utility. The internet community is engrossed in a lively debate about the upcoming release of two new richland desktop processors from amd. During post, the lsi software raid configuration utility automatically detects the installed sata hard disk drives and displays any existing raid set s.
Lsi Software Raid Configuration Utility Serial Number Of TheASUS ASSUMES NO RESPONSIBILITY OR LIABILITY FOR ANY ERRORS OR INACCURACIES THAT MAY APPEAR IN THIS MANUAL, INCLUDING THE PRODUCTS AND SOFTWARE DESCRIBED IN IT. SPECIFICATIONS AND INFORMATION CONTAINED IN THIS MANUAL ARE FURNISHED FOR INFORMATIONAL USE ONLY, AND ARE SUBJECT TO CHANGE AT ANY TIME WITHOUT NOTICE, AND SHOULD NOT BE CONSTRUED AS A COMMITMENT BY ASUS. IN NO EVENT SHALL ASUS, ITS DIRECTORS, OFFICERS, EMPLOYEES OR AGENTS BE LIABLE FOR ANY INDIRECT, SPECIAL, INCIDENTAL, OR CONSEQUENTIAL DAMAGES (INCLUDING DAMAGES FOR LOSS OF PROFITS, LOSS OF BUSINESS, LOSS OF USE OR DATA, INTERRUPTION OF BUSINESS AND THE LIKE), EVEN IF ASUS HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES ARISING FROM ANY DEFECT OR ERROR IN THIS MANUAL OR PRODUCT. ASUS PROVIDES THIS MANUAL AS IS WITHOUT WARRANTY OF ANY KIND, EITHER EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED TO THE IMPLIED WARRANTIES OR CONDITIONS OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. Product warranty or service will not be extended if: (1) the product is repaired, modified or altered, unless such repair, modification of alteration is authorized in writing by ASUS or (2) the serial number of the product is defaced or missing. No part of this manual, including the products and software described in it, may be reproduced, transmitted, transcribed, stored in a retrieval system, or translated into any language in any form or by any means, except documentation kept by the purchaser for backup purposes, without the express written permission of ASUSTeK COMPUTER INC.Using the LSI Software RAID Configuration Utility Before you start Launching the LSI Software RAID Configuration Utility Creating a RAID set Adding or viewing a RAID configuration Initializing the virtual drives ing failed drives Checking the drives for data consistency Deleting a RAID configuration Selecting the boot drive from a RAID set Enabling the Disk Write Cache (DWC) III. This document contains the following sections: I. It also shows the installation of the RAID controller drivers after creating the RAID sets. Launching the LSI Software RAID Configuration Utility To launch the LSI.3 Content This document provides instructions in setting up, creating, and configuring RAID sets using the LSI Software RAID Configuration Utility. LSI Software RAID Configuration UtilityFirmware and utilities to flash on line the LSI MegaRAID SAS 9261-8i adapter.
Lsi Software Raid Configuration Utility Download Drivers ForFor optimal performance, install identical drives of the same model and capacity when creating a disk array. Installing hard disk drives The motherboard supports Serial ATA for RAID set configuration. You can refer to following sections for the instructions in Installing hard disk drives, Setting Jumpers, and Setting the RAID mode in BIOS. Before you start Before you proceed, ensure that you have installed the Serial ATA hard disk drives, set the correct jumper settings of the motherboard, and have set the correct SATA mode in the BIOS setup. Using the LSI Software RAID Configuration Utility The LSI Software RAID Configuration Utility allows you to create RAID 0, RAID 1, or RAID 10 set(s) from SATA hard disk drives connected to the SATA connectors supported by the motherboard. Revision history Revision Revision history Date V1 First release August4 II. Connect a SATA power cable to the power connector on each drive. Connect a SATA signal cable to the signal connector at the back of each drive and to the SATA connector on the motherboard. Install the SATA hard disks into the drive bays following the instructions in the system user guide. Press + to enter the utility. During POST, the LSI Software RAID Configuration Utility automatically detects the installed SATA hard disk drives and displays any existing RAID set(s). Launching the LSI Software RAID Configuration Utility To launch the LSI Software RAID Configuration Utility: 1. Management Menu descriptions below for more information. From the LSI Software RAID Configuration Utility Management menu, use the arrow keys to select an option then press. Otherwise, the system will not boot from the connected SATA ODD. When you create RAID sets with the LSI Software RAID Configuration Utility, the boot priority of the SATA optical drive has to be manually adjusted. The RAID setup screens shown in this section are for reference only and may not exactly match the items on your screen due to the controller version difference. The LSI Software RAID Configuration Utility automatically configures to RAID 1 when the SATA to RAID Mode is enabled. This menu also allows you to view, add, or clear RAID configurations or select the boot drive. Descriptions Menu Description Allows you to create RAID 0, RAID 1 or RAID 10 set using the Easy Configuration or the New Configuration command. LSI Software RAID Configuration Utility Ver C.05 VD(s) Use Cursor Keys to Navigate Between Items And Press Enter To Select An Option Table 1. The keys on the legend box vary according to the menu level. The keys on the legend box allow you to navigate through the setup menu options or execute commands. Loncin 110cc atv partsIn Easy Configuration, the virtual drive parameters are set automatically. Creating a RAID set The LSI Software RAID Configuration Utility allows you to create a RAID 0, RAID 1, or RAID 10 set using two types of configurations: Easy and New. 6 LSI Software RAID Configuration Utility7 3. Allows you to check the data consistency of the virtual drives of a created RAID set. Allows you to rebuild failed drives. Allows you to initialize virtual drives or change the virtual drive parameters. An Array Will Automatically Become A VD Use Cursor Keys to Navigate Between Items And Press Enter To Select An Option 78 2. LSI Software RAID Configuration Utility Ver C.05 Configuration Menu Easy Configuration Management New Menu Configuration View/Add Configuration Clear Configuration Select Boot Drive Defines Physical Arrays. From the, select > Easy Configuration then press. Using Easy Configuration To create a RAID set using the Easy Configuration option: 1. You need at least two identical hard disk drives when creating a RAID 1 set. Easy Configuration - ARRAY SELECTION MENU 0 1 PORT # ONLIN A00-00 ONLIN A READY 3 READY Port # 2 DISK 74.74GB HDS728080PLA C05 SPACE-Sel,ENTER-EndArray,F10-,F2-Drive Info,F3-Virtual Drives,F4-HSP The information of the selected hard disk drive displays at the bottom of the screen. When selected, the drive indicator changes from READY to ONLIN A-, where X is the array number, and Y is the drive number. Use the up/down arrow keys to select the drives you want to include in the RAID set then press. Virtual Drive(s) d LD Easy RAID Configuration Size -#Stripes ARRAY SELECTION StripSz MENU Status PORT # GB 2 64KB ONLINE 0 ONLIN A ONLIN A00-01 Virtual Drive 2 0READY RAID = 1 Units= MB Size = MB DWC = OFF 3 READY RA = On Accept SPAN = NO Choose RAID Level For This VD 6. The virtual drive information appears including a Virtual Drive menu that allows you to change the virtual drive parameters. Press to begin the configuration. Easy Configuration - ARRAY SELECTION MENU Select PORT Configurable # Array(s) A-0 SPAN ONLIN A00-00 ONLIN A00-01 READY READY Cursor Keys, SPACE-(De)Select F2-Chidinfo F3-SlotInfo F10- Esc-Quit 8 LSI Software RAID Configuration Utility9 5. Press to select the configurable array. Select all the drives required for the RAID set then press to configure the array setting. Select Units from the Virtual Drive sub-menu then press. Virtual Drive(s) d LD Easy RAID Configuration Size -#Stripes ARRAY SELECTION StripSz MENU Status PORT # GB 2 64KB ONLINE 0 ONLIN A ONLIN A00-01 Virtual Drive 2 0READY RAID Level RAID = 1 RAID 0 3 READY Units= MB RAID 1 Size = MB DWC = OFF RA = On Accept SPAN = NO Choose RAID Level For This VD10 8. Select the RAID type from the RAID Level sub-menu then press.
0 Comments
Leave a Reply. |
AuthorPatricia ArchivesCategories |